GC6100 Gas Chromatography with FID Detector
Technical Parameters of GC6100 Gas Chromatography
Power Supply | 220V ±10%, 50Hz ±2% |
Ambient Temperature | 5°C to 40°C |
Relative Humidity | 20% to 85% |
Technical Specifications | |
Retention Time repeatability | <0.008% or <0.0008min |
Peak Area Repeatability | ≤0.5% RSD |
Injection Port | |
Injection Port | Split/Splitless |
Maximum Operating Temperature | 450°C |
Control Precision | 0.001 psi |
Control Range | 0–100 psi |
Gas Control Modes | Constant pressure, constant flow, programmed pressure/flow ramps |
Maximum Split Ratio | 12,500:1 |
Optional Carrier Gases | N₂, H₂, He, Ar |
Flow Rate Range (N₂ as carrier gas) | 0–500mL/min |
Column Oven | |
Temperature Range | Ambient +4°C to 450°C |
Programmable Temperature Ramps | 32 steps/33 platforms |
Maximum Heating Rate | ≥75°C/min |
Cooling Time (22°C ambient) | From 450°C to 50°C in <5 minutes |
Maximum Program Run Time | 9999.99 minutes |
FID Detector | |
Maximum Operating Temperature | 450°C |
Minimum Detectability | ≤1.5pg/s |
Linear Range | ≥10⁷ |
DataAcquisition Rate | Up to 1000 Hz (provide proof of software interface) |
ECD Detector | |
Minimum Detectability | ≤4×10⁻¹⁵ g/mL |
Linear Rang | ≥10⁴ |
TCD Detector | |
Sensitivity | ≥60,000 mV·mL/mg |
Linear Range | ≥10⁴ |
Instant Noise | ≤0.1 mV |
Baseline Drift | ≤0.2 mV |
Autosampler | |
Sample Capacity | 16 positions |
Solvent Bottle Positions | 2 |
Waste Bottle Position | 1 |
Syringe Cleaning Modes | Standalone, pre-injection, post-injection |
Injection Volume | 0.1–5μL |
Product Performance
1.1 Very low noise, FID noise is better than the international leading level;
1.2 High sensitivity detector, low baseline drift;
1.3 Good reproducibility of peak area and retention time;
1.4 High temperature control accuracy and good stability, the column thermostat provides a constant temperature environment for the effective separation and detection of various components.
2. Flexibility and scalability
2.1 Optional multiple detectors (FID, FPD, ECD);
2.2 Any two detectors and two chromatographic columns can be installed at the same time; It can have three independent circuits, gas system and three signal output terminals at the same time;
2.3 Flexible syringe injection system, optional autosampler or six-port valve injection.
Product Application
Environmental Protection: Trace Toxicants in Air and Water Contaminated Areas Analysis, monitoring and research
Biochemistry: clinical applications, pathology and toxicology studies.